Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Year range
1.
Rev. latinoam. enferm. (Online) ; 22(5): 842-847, Sep-Oct.2014. tab
Article in English | LILACS, BDENF | ID: lil-730638

ABSTRACT

OBJECTIVE: to relate the variables from a surveillance form for intravenous devices in high risk newborn infants with peripherally inserted central catheter related infection. METHODOLOGY: approximately 15 variables were studied, being associated with peripherally inserted central catheter related infection, this being defined by blood culture results. The variables analyzed were obtained from the surveillance forms used with intravenous devices, attached to the medical records of newborn infants weighing between 500 and 1,499 g. The statistical association was defined using the Chi-squared and Student t tests. The study was approved by the Research Ethics Committee of the Instituto Fernandes Figueira under process N. 140.703/12. RESULTS: 63 medical records were analyzed. The infection rate observed was 25.4%. Of the variables analyzed, only three had a statistically-significant relationship with the blood culture - the use of drugs capable of inhibiting acid secretion, post-natal steroid use, and undertaking more than one invasive procedure (p-value of 0.0141, 0.0472 and 0.0277, respectively). CONCLUSION: the absence of significance of the variables of the form may be related to the quality of the records and to the absence of standardization. It is recommended that the teams be encouraged to adhere to the protocol and fill out the form. .


OBJETIVO: relacionar as variáveis de um formulário de vigilância para dispositivos intravenosos em recém-nascido de alto risco, com infecção relacionada ao uso de cateter central de inserção periférica. METODOLOGIA: foram estudadas cerca de 15 variáveis associando-as à infecção por uso do cateter central de inserção periférica, sendo essa definida pelo resultado da hemocultura. As variáveis analisadas foram obtidas nos formulários de vigilância do uso de dispositivo intravenoso, anexados aos prontuários de recém-nascidos de 500 a 1.499g. A associação estatística foi definida pelos testes qui-quadrado e t de Student. O estudo encontra-se aprovado pelo Comitê de Ética em Pesquisa do Instituto Fernandes Figueira sob nº140.703/12. RESULTADOS: foram analisados 63 prontuários. A taxa de infecção observada foi de 25,4%. Das variáveis analisadas, apenas três apresentaram relação estatisticamente significativa com a hemocultura - o uso de drogas inibidoras de secreção ácida, o uso de esteroides pós-natal e a realização de mais de um procedimento de quebra de barreira (p-valor de 0,0141, 0,0472 e 0,0277, respectivamente). CONCLUSÃO: a ausência de significância das variáveis do formulário pode estar relacionada com a qualidade dos registros e ausência de padronização. Recomenda-se incentivo às equipes para a aderência ao protocolo e preenchimento do formulário. .


OBJETIVO: relacionar las variables de un formulario de vigilancia para dispositivos intravenosos en recién nacido de alto riesgo con infección relacionada al uso de catéter central de inserción periférica. METODOLOGÍA: fueron estudiadas cerca de 15 variables asociándolas a la infección por uso del catéter central de inserción periférica, siendo esta definida por el resultado del hemocultivo. Las variables analizadas fueron obtenidas en los formularios de vigilancia del uso de dispositivo intravenoso anexados a las fichas médicas de recién nacidos de 500 a 1499g. La asociación estadística fue definida por las pruebas Chi-cuadrado y t de Student. El estudio fue aprobado por el Comité de Ética en Investigación del Instituto Fernandes Figueira con el nº 140.703/12. RESULTADOS: fueron analizadas 63 fichas médicas. La tasa de infección observada fue de 25,4%. De las variables analizadas, apenas tres presentaron una relación estadísticamente significativa con el hemocultivo: uso de drogas inhibidoras de secreción ácida, uso de esteroides postnatal y realización de más de un procedimiento de quiebra de barrera (p-valor de 0,0141, 0,0472 y 0,0277, respectivamente). CONCLUSIÓN: la ausencia de significación de las variables del formulario puede estar relacionada con la calidad de los registros y la ausencia de estandarización. Se recomienda incentivar a los equipos para que adhieran al protocolo y al correcto llenado del formulario. .


Subject(s)
Humans , Male , Female , Infant, Newborn , Catheterization, Central Venous/adverse effects , Catheterization, Central Venous/methods , Catheter-Related Infections/etiology , Catheterization, Peripheral , Risk Factors , Catheter-Related Infections/epidemiology
2.
Rio de Janeiro; s.n; 2013. 54 p. tab.
Thesis in Portuguese | LILACS | ID: lil-772783

ABSTRACT

A infecção sanguínea relacionada ao Cateter Central de Inserção Periférica (PICC) se destaca entre as principais intercorrências na utilização deste dispositivo venoso, isto porque indica a necessidade de sua remoção imediata e antecipada, uma vez que a finalidade da instalação do cateter seria permitir um acesso venoso de longa permanência. Esta infecção se dá pela colonização do cateter com migração de microrganismos para o interior da corrente sanguínea, caracterizando uma bacteremia. Diante da possibilidade de ocorrência de complicações pelo uso de cateter, o Center for Disease Control (CDC) disponibilizou o Guidelines for the prevention of intravascular catheter-related infection, cujo objetivo é uniformizar a prática de inserção e manutenção de cateteres intravenosos, entre os quais o PICC. Dentre as muitas recomendações do guia, destaca-se a necessidade de análise periódica da adesão dos profissionais de saúde ao protocolo de controle de infecção, a qual tem por objetivo verificar se medidas de controle e prevenção das complicações infecciosas relacionadas ao uso de cateteres venosos estão surtindo os efeitos esperadosEste estudo, portanto se objetiva a estimar a associação de fatores descritos no formulário de vigilância para dispositivos intravasculares com a incidência de infecção relacionada ao cateter de PICC em recém-nascidos de alto risco. Foram analisados 63 prontuários de recém-nascidos com peso entre 500 a 1500 gramas, que utilizaram PICC quando estavam internados na Unidade de Terapia Intensiva Neonatal do Instituto Fernandes Figueira no período de janeiro de 2009 a dezembro de 2010. Estimou-se que a frequência de infecção pelo uso do cateter nesta população foi de 25,40 por cento...


A bloodstream infection related to Peripherally Inserted Central Catheter (PICC)stands out among the main complications in using this venous device, because it indicates theneed for its immediate removal and anticipated, since the purpose of the installation of thecatheter would allow access Venous long stay. This infection is by colonization of the catheterwith antigen migration into the bloodstream, characterized bacteremia.Faced with the possibility of complications catheter use, the CDC released theGuidelines for the prevention of intravascular catheter-related infection, whose goal is tostandardize the practice of insertion and maintenance of intravascular catheters, including thePICC. Among the many recommendations of the guide, there is the need for periodic reviewof the membership of health professionals to the infection control protocol, which aims todetermine whether measures of control and prevention of infectious complications related tothe use of venous catheters are having an expected effects.This study therefore aims was to assess the association of factors described in the formof surveillance devices with the incidence of intravascular catheter-related infection PICC ininfants at high risk.We analyzed medical records of 63 neonates weighing 500-1500 grams, which whenused PICC were admitted to the Neonatal Intensive Care Unit of the Fernandes FigueiraInstitute from January 2009 to December 2010. It was estimated that the frequency of catheterinfection in this population was 25.40 percent...


Subject(s)
Infant, Newborn , Blood Circulation , Catheter-Related Infections/physiopathology , Catheter-Related Infections/transmission , Infant, Newborn/blood , Technology Assessment, Biomedical , Brazilian Health Surveillance Agency
SELECTION OF CITATIONS
SEARCH DETAIL